IDES
Plastics   Generics   Properties   Manufacturers   Articles   Webinars
Login to Prospector
Don't have an IDES account?
Create an account now
Results 1 - 10 of 72 documents for

gate land length

Share This Page Share This Page  •  Free Access to 80,000 Datasheets
ABS TroubleShooting
Decrease mold temperatures Analyze gate location and relocate as needed Decrease gate land length to improve cavity pack Check for a worn check valve assembly, barrel or screw...
www.ides.com/generics/ABS/ABS_troubleshooting.htm - More results from www.ides.com
[pdf] Hot Runner Systems TECHNICAL MANUAL CATALOGUE
the gate. (Note: gate cooling is a complex variable, cycle time, gate profile and land length are also involved) These variables interact as per the diagrams below: � �...
www.mastip.com/...hnical%20Manual%20A.2%2008-2003.pdf - More results from www.mastip.com
Engineering Plastics Gate Type
size is 80% to 100% of the part thickness up to 3.5 mm and 1.0 to 12 mm wide. The gate land should be no more than 1.0 mm in length, with 0.5 mm being the optimum. Edge gate View...
www.dsm.com/en_US/html/dep/gatetype.htm - More results from www.dsm.com
GE Plastics - Glossary
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # L/D Ratio Lab Land (Gate Area) Land Area Light Light Fastness Light Source Light Transmission Lightness Limiting Oxygen...
www.sabic-ip.com/gepapp/controller?letterSelected=L - More results from www.sabic-ip.com
[pdf] Microsoft PowerPoint - moulddesign_for_marplex_etps.ppt
for nozzle seal-off and seating. The orifice (gate) should be a minimum of 3.2mm and a land length can be minimized by sinking 1.5mm to 2.3mm from cavity end. Counter sinking...
www.marplex.com.au/..._N_Die_for_Marplex_Polymers.pdf - More results from www.marplex.com.au
[pdf] T20 R3
è Valve gate: VG12 & VG23 tapered gate VG12S & VG23S straight gate J Nozzle length Band heated 160-380 Helical heated 160-500 Nozzle flow bore Ø10-20 *D Ø50(band),...
www.synventive.com/...stems/Nozzles/PDFs/T20%20R4.pdf - More results from www.synventive.com
[pdf] http://www.mdayinc.com/guides...
sensitive a) Polish gate area to eliminate rough areas and sharp edges b) Decrease gate land length Gate size should be 50-80% of the nominal wall thickness Remove color...
www.mdayinc.com/..._molding_troubleshooting_guide.pdf - More results from www.mdayinc.com
[pdf] HRUM Section 12 Troubleshooting.indd
machine for irregularities * Balance regrind ratio * Increase gate size * Decrease gate land length * Balance the runner and/or gate system * Decrease cavity quantity �...
www.moldmasters.com/...920-4dad-b1a0-612d69552041.pdf - More results from www.moldmasters.com
[pdf] Formolene
be dependent upon factors like: part and tooling design, wall thickness, flow lengths, gate size, number of cavities, cycle time and desired level of molded part quality, for...
www.southlandpolymers.com/...C%20PP%20Inj%20Guide.pdf - More results from www.southlandpolymers.com
Santoprene Specialty Products :: Splay Marks In Gate Area
drop between an injection molding machine and a mold cavity. Shortening the land length of the gate will also help regulate pressure and aid in heat retention. Did this...
www.santoprene.com/cms/site/ad545fa537d84b28/ - More results from www.santoprene.com
Results Page: 1 2Next >
 
Articles
More Articles
Gate Defects &am Design: IDES - The Plastics...
The package contained many small lenses, each one showing a different problem with cosmetic issues at the gate. The small cold runner that accompanied the parts was a classic example of what not to do when designing a gate to feed a part that requires high clarity and no blemishes.
Gates & Amorphous Materials: IDES - The Plastics...
The runner was trapezoidal, which is not correct for an edge gate, and the runner and gate design were unusual for a clear, amorphous material. I guessed it was a hard-surface acrylic, but I didn’t want to burn it to see if the smell gave it away.
Basics of Tab Gates: IDES - The Plastics...
This month’s discussion revolves around a flat, edge-gated part. In this case, a tab gate is used as the edge gate.
Share This Page - Services - Advertise With Us - About IDES - Contact Us NA: 800-788-4668, 307-742-9227  |  EU: 0033 (0) 471 759 577 Chat ©1986- IDES